Detail Specifications
Overall Height:
3.000 inches
Body Length:
2.750 inches
Body Height:
2.500 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.500 inches
Vibration Resistance Range In Hertz:
+10.0/+2000.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.500 inches
Operating Tempurature Range:
-54.0/+85.0 degrees celsius
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Input Impedance Per Function W/load:
50.0 ohms 2nd radio interference
Input Impedance Per Function W/load:
50.0 ohms 3rd radio interference
Input Impedance Per Function W/load:
50.0 ohms 4th radio interference
Input Impedance Per Function W/load:
50.0 ohms 5th radio interference
Input Impedance Per Function W/load:
50.0 ohms 6th radio interference
Input Impedance Per Function W/load:
50.0 ohms 1st radio interference
Output Impedance Per Function W/source Across Input:
50.0 ohms 2nd radio interference
Output Impedance Per Function W/source Across Input:
50.0 ohms 3rd radio interference
Output Impedance Per Function W/source Across Input:
50.0 ohms 1st radio interference
Output Impedance Per Function W/source Across Input:
50.0 ohms 4th radio interference
Output Impedance Per Function W/source Across Input:
50.0 ohms 5th radio interference
Output Impedance Per Function W/source Across Input:
50.0 ohms 6th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Operating Current Rating Per Function In Amps:
1.0 1st radio interference
Operating Current Rating Per Function In Amps:
1.0 3rd radio interference
Operating Current Rating Per Function In Amps:
1.0 4th radio interference
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference
Operating Current Rating Per Function In Amps:
1.0 5th radio interference
Operating Current Rating Per Function In Amps:
1.0 6th radio interference
Maximum Voltage Drop Per Function:
2.5 volts ac 1st radio interference
Maximum Voltage Drop Per Function:
2.5 volts ac 3rd radio interference
Maximum Voltage Drop Per Function:
2.5 volts ac 2nd radio interference
Maximum Voltage Drop Per Function:
2.5 volts ac 4th radio interference
Maximum Voltage Drop Per Function:
500.0 millivolts dc 5th radio interference
Maximum Voltage Drop Per Function:
500.0 millivolts dc 6th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
Mounting Facility Screw Thread Series Designator:
Unc
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
4 threaded hole
Functional Terminal Type And Quantity:
2 tab, solder lug ground 3rd function
Functional Terminal Type And Quantity:
6 tab, solder lug output 2nd function
Functional Terminal Type And Quantity:
6 tab, solder lug input 1st function
Maximum Dielectric Withstanding Ac Rms Voltage:
350.0 volts at sea level
Operating Voltage Rating And Type Per Function:
28.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 6th radio interference 6th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
Thread Size:
0.112 inches
Maximum Dielectric Withstanding Dc Voltage:
100.0 volts at sea level
Style Designator:
Rectangular terminal/terminals on one surface
Item Name:
Electromotive Force Interference Filter
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC